The mark is not just identification — on regulated products it is a legal requirement with defined data content and a measurable print quality. What must be on it is set by the market and the product class, not by the machine vendor: EU medicine packs need a serialised DataMatrix, re-usable medical devices need a permanent identifier on the device itself, and almost everything needs a batch and a date that a stranger can read.
This page is a map of obligations, assembled from published standards and regulation. It is not legal advice. Standards change; verify against the current text before you sign anything. Where a date is given, it is the compliance anchor in the cited regulation — exceptions exist.
Strip the regimes down and four data items keep reappearing. If your mark carries all four, you are close to compliant almost everywhere; if it misses one, no printer brand will save the pack.
Serialisation adds a fifth item — uniqueness per unit — and it is the one that changes the production line, because uniqueness cannot be printed from a template. It needs a controller, a camera, and a decision about what to do when a code fails.
The second thing the regimes have in common is that they measure the mark instead of looking at it.
The distinction that matters on the line: a scanner tells you this code read. A verifier tells you this code will keep reading — under different light, on a different scanner, six months from now. A line judged by whether the camera happened to read a code is running on luck; a line judged by grade is running on margin.
"The DataMatrix shall grade 1.5 or better (ISO/IEC 15415) on a calibrated verifier, at minimum and maximum line speed, on production material." A grade with a method attached can be written into a purchase order; "readable code" cannot. The measurement moment belongs in acceptance testing, not after installation.
| Regime | Where | Applies to | The mark must carry | Anchor date |
|---|---|---|---|---|
| EU FMD 2011/62/EU + Reg (EU) 2016/161 | EU / EEA | Human medicine packs (most; a listed few exempt) | Unique identifier — product code + serial number + batch + expiry — in a GS1 DataMatrix, plus a tamper-evident device | 9 Feb 2019 |
| US DSCSA | United States | Prescription drugs, down to the saleable unit | Product identifier (NDC or GTIN) + serial + lot + expiry, DataMatrix | Enforced from late 2023, discretion through 2024 |
| US UDI 21 CFR 801 / 830 | United States | Medical devices | UDI on the label; direct marking on the device for re-usable instruments — Class II direct mark from Sept 2018, Class I from Sept 2020 (Class III 2016, implantable/life-supporting 2015) | Phased 2014–2020 |
| EU MDR (EU) 2017/745 | EU / EEA | Medical devices | UDI carrier on labels and packaging, Basic UDI-DI in the database, direct marking for re-usable devices | Phased since 2021 |
| GS1 general | Global | Retail and consumer goods | GTIN plus application identifiers: (10) batch, (11) production date, (17) expiry. DataMatrix/QR widely used off-shelf; POS still expects the barcode | — |
Compliance anchors, not a complete statement of the law — each regime has exceptions, grace periods and enforcement policies of its own. Confirm against the current text. Cable-specific field requirements are covered in what the mark must carry on cable.
Not the printer vendor, and mostly not customs. The people downstream of your line check:
The practical consequence: a marginal code is not an aesthetic problem. It is a rejection waiting at the least forgiving reader in the chain.
Three clauses turn this page into something enforceable on your line:
The full FAT/SAT structure these clauses fit into is in acceptance testing.
No. The grade floor applies where a regime requires it — the healthcare DataMatrix under GS1 healthcare and EU medicines verification is the common case. Internal codes still need to read reliably, but there is a difference between a scan target and a regulated quality attribute. Check which one your code is before buying a verifier.
Regulated pharma marks in practice are GS1 DataMatrix (or HIBC). QR appears in consumer-facing contexts — marketing, provenance apps — but pharmacy scanning and verification infrastructure expects DataMatrix. Choosing QR for a regulated pack is a question for the marketing department and the regulator, in that order of who says no.
Often they can, but treat it as a purchase decision, not an accessory. What matters is that the verifier is calibrated, its grading standard is the one your regime cites, and someone on your side knows how to interpret a grade report beyond "it passed".
The pack is rejected at the point of dispensing and the failure is reportable. Above a threshold of failures, the question stops being "which pack" and becomes "which batch" — which is why grade margin at the factory is cheaper than lot investigations later.
The US rule (21 CFR 801.45) does not prescribe a method — etching, plates, tags are all named in FDA guidance — but the mark must last through the device's expected service life including reprocessing. Laser and indent are both used; the deciding test is survival through the actual cleaning chemicals and cycles, not how the mark looks on day one.
They are a different regime — not about data content but about what may migrate from the mark into food. That is covered in the food and beverage guide.
What food law does to the mark — condensation, washdown and the food-contact boundary.
Related
Pages that connect to this one.
Field-by-field requirements on the one product where the mark is a measurement.
What serialisation does to a production line, end to end.
Condensation, washdown and the food-contact boundary.
Where the grade clause and the verifier check belong.